Change the electro (When the electrode discharge time over 5000~6000 times) 1. Screw off the bolt which fix the electro 2. Take off the old electro 3. change to the new electro, screw on the bolt and fix it 4. The same step to change another electrode
-
1: Use the cotton bud dip with the alcohol (After work in the dusty place) 2:Clean the V-groove in one way direction 3: Use the dry cotton bud to clean the lens (Take the note that must use the dry cotton to clean the lens, wipe the lance by the cotton bud with alcohol will make damage for the lens)
-
Heating the shrink sleeve: ((Every time after do the splicing, will do the heating shrink sleeve) 1: Move the shrink sleeve to the splicing point, (caution, do not break the splicing point) 2:Put the shrink sleeve into the heat oven 3:Press “HEAT”, and the LED turn red. 4. After the “red” LED turn black, finish the heating, take out the shrink sleeve.
-
Splicing: Prepare: Fusion Splicer, Fiber cleaver, fiber coat stripper, Alcohol cotton& Bottle 2: Strip the fiber about 20~25mm 3: use the alcohol to clean the bare fiber 4: Before cleaver the fiber, please posit the slide to the right position 5. Put the cleaned bare fiber on the fiber cleaver: 16mm scale 6. Posit the fiber on the fiber cleaver 7. Push the slide of the fiber cleaver following the arrow direction (see the following pic), cleave the fiber 8:Take out the cleaved fiber, please take notice that the end face of the cleaved fiber do not touch any other things. 9:Open the windshield, placing the fiber 10:posit it near the Electrode-end, but notice please do not over it! 11. the same step, for the other fiber—cleave and posit it. 12:Close the windshield, press :RUN 13:GAP 14: Complete the splicing. 15: ARC Test (The first time use the fusion slicer should do this test) The same step with the previous--cleave and posit the fiber, just in the last step, press test instead of pressing Run button 16:After press test, the LCD will display “ POWER OK”, means finish the ARC test. If displaying "POWER HIGH" or "POWER LOW" we should re-do the ARC test for one or two times again, still the LCD displaying “ POWER OK”